INSTALLATION INSTRUCTIONS
IMPORTANT: The packing elements (foamed polystyrene, plastic bags) must be kept out of the reach of children, as
they are a potential source of danger.
This boiler has been designed to respond to European standards. It has been manufactured with greatest care, in compliance with
safety regulations. Each appliance has been tested when working, and the inspector who carried out the tests has signed the
warranty certificate enclosed with the appliance documents.
Check that the boiler supplied corresponds perfectly with its intended use.
-Indications of the type of boiler and gas to be used are given on the plate fitted behind the control panel, outside the boiler and on
the boiler packaging.
The products described in this manual have been correctly manufactured in conformity with current legislation.
The boilers are manufactured in accordance with EN specific safety Standards for fuel gas, as per Directive 90/396/CEE regarding
gas appliances and Directive 92/42/CEE regarding performance levels of new hot water boilers, that are driven by liquid or gas
fuels.
This appliance must be installed in accordance with the following Statutory Regulations and British Standards Codes of Practice:
Building Regulations (England and Wales). The Buildings Standards (Scotland) Regulations. Gas Safety (Installation and Use)
Regulations 1984. Current I.E.E. Wiring Regulations and Local Water Authority By-Laws.
Codes of practice: BS.6891 –Installation of low pressure gas pipework;
BS.6798 –Installation of gas fired hot water boilers of a rated input not exceeding 60 kW.
BS.5449:1 –Forced circulation hot water system (domestic central heating system smallbore and microbore).
BS.5546 –Installation of gas hot water supplies for domestic purposes (2
nd
family gases).
BS.5440:1 –Flues (for gas appliances of rated input not exceeding 60 kW).
BS.5440:2 –Air supply (for gas appliances of rated input not exceeding 60kW).
TECHNICAL SPECIFICATIONS
Mod. Zoom Z 420A – Z 520A ZF 420A – ZF 520A
Configuration
B
11BS
C
12
C
32
C
42
C
52
B
22
Rated heat throughput (P.C.S.)
Btu / h - kW
97,490 –
28.6 97,490 –
28.6
Reduced heat throughput
(P.C.S.)
Btu / h - kW
47,275 –
13.86 48,745 –
14.3
Rated heat output working
Btu / h - kW
80,000 –
23.45 80,170 –
23.49
Reduced heat output working
Btu / h - kW
36,845 –
10.8 38,210 –
11.2
Working thermal efficiency at rated power (P.C.I.)
%
90.2 90.4
Energy efficiency
Working thermal efficiency at 30% of rated power (P.C.I.)
%
87.4 88
Lose of heat from casing (
%
2.5 2
Lose of heat through the chimney with the burner alight
%
5.8 6.5
Lose of heat through the chimney with the burner turned off %
0.8 1.1
Max. working pressure of the heating circuit
P.S.I.
- bars
42.67 - 3 42.67 - 3
Adjustable temperature in heating mode
°F - °C
86 / 176 - 30 / 80 86 / 176 - 30 / 80
Expansion tank – total volume
gals - litres
1.32 / 1.54 - 6 / 7 1.32 / 1.54 - 6 / 7
Rated heat throughput in sanitary mode (P.C.S.) D.H.W.
Btu / h - kW
97,570 –
28.6 97,570 –
28.6
Reduced heat throughput in sanitary mode D.H.W. Btu / h - kW
36,504 –
10.7 36,504 –
10.7
Rated heat output in heating mode D.H.W. Btu / h - kW
80,000 –
23.45 80,716 –
23.62
Reduced heat output (working) in sanitary mode D.H.W. Btu / h - kW
31,727 –
9.3 31,727 –
9.3
Adjustable temperature in sanitary mode
°F - °C
95 / 131 - 35 / 55 95 / 131 - 35 / 55
Max. water available with continuous working (t 35°C)
gals - litres/min
2.13 – 9.6 2.13 – 9.6
Specific flow rate (EN 625)
gals - litres/min
2.51 - 11.3 2.51 - 11.3
Minimum sanitary water flow rate
gals - litres/min
0.62 – 2.8 0.62 - 2.8
Minimum / maximum D.H.W. sanitary water pressure
P.S.I.
- bars
0.02 / 1.55 - 0.1 / 7 0.02 / 1.55 - 0.1 / 7
Electric connections
V / Hz
230 / 50 230 / 50
Rated absorption
A
0.5 0.8
Electric appliance protection
IP
X4 D X4 D
Maximum electricity consumption
W
90 140
CO
2
content (methane) “B” type boilers % rated – reduced 4.8 – 2.7 ---------
CO
2
content (methane) “C” type boilers •••
% rated – reduced --------- 5.75 – 2.75
CO
2
content (LPG G30) “B-C” type boilers % rated – reduced 6 – 3.6 6.95 – 3.85
Flue flow rate in weight (methane: G20)
g/s rated – reduced
20.6 – 17.2 17.5 – 17.4
Flue flow rate in weight (LPG: G30)
g/s rated – reduced
19 – 15 16.7 – 14.5
Fume temperature (methane: G20)
°C rated – reduced
105 – 90 102 – 93
Fume flow rate in weight (LPG: G30)
°C rated - reduced
104 – 83 116 – 105
With coaxial pipe, max. length 3 metres.